Cowtown ProsGet featured

Home / Guides / AC and heating

What SEER2 ratings mean when you buy a new AC

SEER2 measures how much cooling an AC delivers per unit of electricity over a season. Here's the Texas minimum, the ENERGY STAR level and how to compare.

The short answer

SEER2 is the federal efficiency rating for central air conditioners and heat pumps: the cooling delivered over a season divided by the electricity used, so higher means cheaper to run. In Texas, a new split or packaged central AC installed since January 1, 2023 must be at least 14.3 SEER2 under 45,000 Btu per hour (13.8 at larger sizes), and ENERGY STAR certification starts at 15.2 SEER2.

Key points

  • SEER2 replaced SEER on January 1, 2023, after DOE changed the test, and the two numbers aren't directly comparable.
  • Texas is in DOE's Southeast region, where new central AC must meet 14.3 SEER2 below 45,000 Btu per hour and 13.8 SEER2 at or above it.
  • ENERGY STAR central air conditioners need at least 15.2 SEER2 and, for split systems, 12.0 EER2.
  • The rating depends on the indoor and outdoor parts working together, and on a good installation.
  • The federal home energy tax credit covered equipment placed in service through 2025, according to the IRS.

What does SEER2 mean?

If you're asking what SEER2 means, it stands for seasonal energy efficiency ratio, version 2. ENERGY STAR's specification defines it as the total heat removed from your home over the cooling season divided by the electricity the system uses over that same season. A higher SEER2 means more cooling for each kilowatt-hour you pay for.

You'll see two related numbers on spec sheets. EER2 is the ratio of the average rate of cooling to the average rate of electricity used, measured at a set condition rather than across a season. HSPF2 is the heating rating for heat pumps, the heat delivered over the heating season divided by the electricity used.

TipWhen two proposals list different SEER2 numbers, ask each company for the exact indoor and outdoor model numbers so you can check the rating yourself.

SEER vs SEER2: why the number changed

Starting January 1, 2023, the U.S. Department of Energy required a revised test procedure for central air conditioners and heat pumps, and the ratings it produces are called SEER2, EER2 and HSPF2. DOE says the new ratings are similar to the old SEER, EER and HSPF but not directly comparable.

So don't line up a SEER number from an old brochure or your old unit's label against a SEER2 number on a new quote and assume they mean the same thing. Compare SEER2 with SEER2.

The minimum SEER2 for a new AC in Texas

Federal minimums for central air conditioners vary by region, and Texas is in DOE's Southeast region. For split-system and single-package air conditioners installed on or after January 1, 2023, the Southeast minimum is:

  • 14.3 SEER2 for systems under 45,000 Btu per hour of cooling capacity.
  • 13.8 SEER2 for systems at or above 45,000 Btu per hour.
  • No separate EER2 minimum in the Southeast. The Southwest region (Arizona, California, Nevada and New Mexico) has one.

Heat pumps follow national minimums instead of regional ones. A new split-system heat pump must be at least 14.3 SEER2 and 7.5 HSPF2, and a single-package heat pump at least 13.4 SEER2 and 6.7 HSPF2.

In the Southeast, DOE ties the rule to the installation date, which it defines as connecting the refrigerant lines or electrical so the unit runs. That's why a contractor can't install old stock that misses the current minimum, even if it's been sitting in a warehouse.

ENERGY STAR and higher SEER2 levels

ENERGY STAR's current specification for central air conditioners sets these minimums:

  • Split systems: at least 15.2 SEER2 and 12.0 EER2.
  • Single-package units, including gas and electric packages: at least 15.2 SEER2 and 11.5 EER2.
  • Split-system heat pumps: at least 15.2 SEER2, 11.0 EER2 and 7.8 HSPF2.

How much a higher rating saves depends on your electric rate, how much you run the AC and how long you keep it. For federal buyers in the Southeast, DOE's Federal Energy Management Program estimates that a 15.2 SEER2 ENERGY STAR unit saves $1,853 over an 18-year life compared with a 13.4 SEER2 unit, and that the best available model at 23.5 SEER2 saves $6,724, in 2023 dollars. Those are DOE's planning figures with its own assumptions, not a promise for your house.

The question for you is whether the extra cost of the higher-rated system pays back over the years you expect to stay. Ask each company to show its savings estimate and the electric rate it used.

Why the rating depends on the whole system and the install

A SEER2 rating belongs to tested equipment, and real-world results depend on how it's matched and installed. DOE says that in the Southeast a new outdoor unit paired with an existing indoor coil can be installed only if it's certified as meeting the regional standard in that no-match setup. Ask for the rating of the exact combination you're buying.

Installation matters as much as the label. DOE's federal buying guide says oversizing, improper charging and leaky ducts cause efficiency losses, and ENERGY STAR says improper installation can reduce system efficiency by up to 30 percent. DOE adds that split systems with the correct refrigerant charge and airflow usually perform close to their rated efficiency.

To check a rating, DOE points buyers to the yellow EnergyGuide label, ENERGY STAR's certified product list and the CEE-AHRI directory. The FTC says EnergyGuide labels cover central air conditioners, heat pumps and furnaces, and you can find them on the unit or on the seller's or manufacturer's website.

Questions to ask about SEER2 before you buy

Bring the same list to every company so the answers line up. If one proposal shows only a brand and a size with no model numbers, ask for them before you compare prices, because you can't check a rating you can't see.

  1. What are the exact model numbers of the outdoor unit and the indoor coil or air handler?
  2. What is the SEER2 and EER2 rating of that exact combination?
  3. Does it meet the Southeast minimum, and is it ENERGY STAR certified?
  4. How did you size it, and will you test the refrigerant charge and airflow after installation?
  5. What would a lower or higher SEER2 option cost, and what savings are you estimating for each?

On tax credits, be careful with older advice. The IRS says the Energy Efficient Home Improvement Credit applies to qualifying property placed in service on or after January 1, 2023, and before December 31, 2025, and its page doesn't mention an extension. Check with a tax professional about your own return. Cowtown Pros ranks local AC companies on what their own websites show, which can help you find companies to ask these questions.

Comparing ac and heating companies? We checked Fort Worth ones against the same list, using only what their own websites show.

Best AC and Heating Companies in Fort Worth

FAQs

What is the minimum SEER2 rating in Texas?

Texas is in DOE's Southeast region, where a split or single-package central AC installed since January 1, 2023 must be at least 14.3 SEER2 below 45,000 Btu per hour and 13.8 SEER2 at or above that size.

Is 16 SEER the same as 16 SEER2?

No. DOE says SEER2 comes from a revised test and isn't directly comparable to the older SEER number, so compare SEER2 ratings only with other SEER2 ratings.

What SEER2 rating qualifies for ENERGY STAR?

ENERGY STAR's current specification requires at least 15.2 SEER2 for central air conditioners, plus 12.0 EER2 for split systems and 11.5 EER2 for single-package units.

Can I still get a federal tax credit for a high-SEER2 AC?

The IRS says the Energy Efficient Home Improvement Credit covers qualifying property placed in service from January 1, 2023, and before December 31, 2025. For a system installed later, ask a tax professional before counting on any credit.

Sources

Every rule and figure in this guide comes from one of these pages, which we read in November 2026. Rules change, so check the agency's own page before you rely on it.

  1. U.S. Department of Energy: 2023 Central Air Conditioner Standards FAQ
  2. ENERGY STAR: Program Requirements for Central Air Conditioners and Air Source Heat Pumps, Version 6.2
  3. U.S. Department of Energy FEMP: Purchasing Energy-Efficient Residential Central Air Conditioners
  4. U.S. Department of Energy: Air-Source Heat Pumps
  5. ENERGY STAR: Heating and Cooling
  6. FTC: How To Use the EnergyGuide Label To Shop for Home Appliances
  7. IRS: Energy Efficient Home Improvement Credit

See something wrong or out of date? Request a correction